LP4502 Controller Setup

LP4502 Controller Setup

1.0 Introduction

LP4502 Controller


The new Authentic Mercury LP Series Intelligent Controllers are Mercury Security’s next generation advanced access control platform that runs on embedded Linux. The enhanced platform offers an improved processor and increased memory, plus feature an embedded crypto memory chip that provides a secured layer of encryption to onboard sensitive data. Built on the Authentic Mercury open platform, LP Series controllers provide the necessary flexibility for OEMs, channel partners and end customers to choose the controller configuration that best fits their needs.

 

Note: Borealis is also fully compatible with the (series 2) EP4502 controller types.

 

The setup for the LP-4502 controller is very similar to the LP-1502 and the LP-2500. All LP controllers are pre-configured for use on a network, therefore additional TCP/IP configuration must take place in the field prior to placing each unit into service. The LP4502 is an example of a System Processing Module (SPM) and is configured with a web browser. You can connect to the controller via Ethernet, using the static IP address or DHCP. This setup guide covers how to add the controller to Borealis using the DHCP IP address assignment method.

 

2.0 Main Features

  • Multi-card and multi-reader technology support

  • Two-door interface with auxiliary I/O
  • 8 inputs and 4 outputs
  • Scalable up to 32 doors per hub
  • Multiple credential format support

  • Multiple reader and keypad support (including OSDP readers)
  • HSPD-12/FIPS201 compliant

  • UL 294 certified
  • Utilizes the Linux operating system for extensive communications support and heightened IT security capabilities.

 

 

3.0 Bulk Eraze and Configure the Controller for DHCP

Before setting up a Mercury intelligent controller, a bulk eraze should be performed to remove all existing configuration.

 

Because Borealis operates on a DHCP network, the controller will also need to be set to DHCP using the S1 dip switch. This will configure the controller to obtain an IP address from the DHCP network that the Borealis hub is added to. The following steps explain how to perform the bulk eraze and then to set the controller to a normal operating mode (and a DHCP configuration).

 

  1. Power down the controller.
  2. Set the DIP switches S1 and 2 to the ON position.

    Bulk eraze

  3. Power-up the controller.
  4. LEDs 1,2,3 and 4 will start flashing alternately at a rate of 0.5 seconds.
  5. Wait for these 4 LEDs to stop flashing.
  6. Within 10 seconds of these LEDs no longer flashing, set switches 1 and 2 into the off position. All 4 switches should then be in the off position.

    Normal Mode

  7. The controller memory will now be erazed. Full memory eraze takes up to 60 seconds.
  8. Wait at least 2 minutes for the controller to obtain a DHCP address from the DHCP network.

 

 

4.0 Add the LP4502 Controller via the Scan Function

This section assume that you have an existing Borealis system and you have already added a Mercury site and have also added and claimed a hub to that site. The hub should be online and updated, only then will you be able to scan for the LP4502 controller.

 

  1. From Borealis, click Hubs from the main menu.

    hubs

  2. Your online hub should be displayed.
  3. Click the SCAN button located on the right-side of the screen.
  4. The hub will scan the local DHCP network for the LP4502 controller.
  5. The controller will be detected and you will see the assigned DHCP address and MAC address.
  6. Place a check mark against the controller and enter a new description.

    LP4502 Detected

  7. Click the CLAIM button on the right side of the screen.
  8. The new controller will be added to the system.
  9. Go to Hardware >> Controllers and you will see the new controller listed.

 

 

5.0 Manually Add the LP4502 Controller

If you know the LP4502 controller's programmed IP address (for example, if the controller has been setup externally via a web browser), you can manually add the controller.

 

  1. From the main menu, click on Hardware >> Controllers.
  2. The controller screen will appear.
  3. On the right-side of the screen click the ADD CONTROLLER button.
  4. Enter a name for the controller.
  5. Select the hub that the controller will be added to.
  6. Select the specific controller type from the drop-down list.
  7. Enter the IP address that is pre-programmed on the controller.
  8. Enter the controller's MAC address (this is printed on the side of the controller's Ethernet port) it begins 00-0F-E5.

    Add controller form

  9. Click the SAVE button.

 

 

6.0 Memory Reset the New Controller

A newly added controller will require a memory reset. After adding the new controller you will see an orange indicator next to the controller name. Hover over this indicator and you will see that it is an indicator to reset the controller memory.

 

Memory reset indicator

 

 

  1. From the Actions menu on the right select Reset.

    Controller reset

  2. A prompt will appear informing you that the reset will clear the existing data on the controller but the controller will retain its network settings.
  3. Click the MEMORY button and the controller will be reset.

    reset prompt

  4. During the reset procedure the controller will go offline for a few seconds. When the controller comes back online the memory reset indicator will be cleared.

    • Related Articles

    • LP1502 Controller Setup

      1.0 Introduction The LP1502 is a powerful system processor module capable of managing two doors/readers “on board” and hundreds of I/O points via connection to additional door modules or MR16 I/O modules. Based on the intelligent, non-proprietary ...
    • EP4502 Controller Setup

      1.0 Introduction The EP4502 is a powerful system processor module capable of managing two doors/readers “on board” and hundreds of I/O points via connection to additional door modules or MR16 I/O modules. Based on the intelligent, non-proprietary ...
    • EP1502 Controller Setup

      1.0 Introduction The EP1502 is a powerful system processor module capable of managing two doors/readers “on board” and hundreds of I/O points via connection to additional door modules or MR16 I/O modules. Based on the intelligent, non-proprietary ...
    • NXT-MSC Controller Setup

      1.0 Introduction The following steps explain how to add an NXT-MSC controller to Borealis. It assumes that you have already followed the steps to add an NXT-MSC site to your system. During the steps to claim the hub you will select the site that the ...
    • MR62E Controller Setup

      1.0 Introduction The following steps explain how to add an MR62E controller to Borealis. The most important thing to be aware of is the fact that you must first add an LP4502 controller to Borealis before you can add the MR62E. 2.0 Add an LP4502 and ...