Mercury EP Controllers - Assign a Static IP Address

Mercury EP Controllers - Assign a Static IP Address

Configure the Mercury EP Controller With a Static IP Address

Once the controller has been added to Borealis you should configure it with a static IP address. This can be done via the controller's Internal Configuration menu.

Important Note: Before assigning the controller with a static IP address you should ensure the IP address you wish to assign is not already assigned to another device on the network.

  1. From the Borealis main menu, click on Hardware >> Controllers.



  2. Locate the controller that you have added.
  3. Use the controller's Actions menu located on the right side of the screen and select Configure.



  4. The Internal Configuration form will appear.
  5. From the drop-down menu, select Network.
  6. You will see that by default the Network Method is set to DHCP.
  7. Change the Network Method to Static and then enter the static IP address you wish to assign to the controller.



  8. The Subnet Mask and Default Gateway should not be edited.
  9. Click the SAVE button.
  10. Next, click the APPLY CHANGES and Reboot button.
  11. You will see a notification prompting you to confirm the reboot.



  12. Click Yes to proceed.
  13. The controller will reboot and it will momentarily go offline.
  14. Within a few seconds the controller should be back online and the new, static IP address will be displayed.



    • Related Articles

    • NXT-MSC Controller - Assign a Static IP Address

      Configure the Controller With a Static IP Address Once the NXT-MSC controller has been added to Borealis you should configure the controller with a static IP address. This can be done via the controller's Internal Configuration menu. Important Note: ...
    • Add Controllers

      Add a New Controller (NXT, KB or NXT-MSC) The process of adding a controller to Borealis is the same regardless of the controller type being installed (the steps apply to both NXT and NXT-MSC controllers). The only difference is that Standard NXT and ...
    • Elevator Control - Using True Mercury Controllers

      1.0 Introduction Borealis provides a cost-effective elevator control solution using NXT-MSC controllers with 4x4 modules or with MR16 modules and True Mercury controllers with MR16 modules. Elevator control uses a reader on the controller's reader ...
    • Elevator Control - Using NXT-MSC Controllers

      1.0 Introduction Borealis provides a cost-effective elevator control solution using NXT-MSC controllers with 4x4 modules or MR16 modules and True Mercury controllers using MR16 modules. Elevator control uses a reader on the controller's bus 1 to ...
    • Add a True Mercury Site

      1.0 Introduction The site determines which hardware type will be used. Once a site has been added you will then be able to add a hub (or multiple hubs) to the site. Each hub supports up to 32 doors. A site may represent a business location, a floor ...