Keri NXT controllers with Mercury Firmware now provide an Entrance/Exit reader door control feature/configuration. This Entrance/Exit feature allows two readers to be wired into one bus on the NXT controller to control entrance and exit through that one door. Access requests entering through the door use a standard NXT-R reader (designated as an Entrance Reader). Access Requests exiting through that same door use an NXT-RE reader (designated as an Exit reader). Otherwise, all specifications and wiring information for the two reader types are identical.
By default all Doors.NET license keys have the NXT Exit reader enabled. Older license keys for NXT Mercury Powered controllers may not have this option enabled. Verify your Doors.NET license has this feature enabled before configuring your entrance and exit readers in the software.
NOTE: The NXT Exit reader can ONLY be used on the NXT Mercury Powered controllers.
An NXT Exit Reader is wired to a bus the same way a standard NXT Entrance Reader is wired, but both readers are wired to the same bus. This can be done using two separate reader cables wired into the terminal block at the bus on the controller, or by splicing the two readers together near the door and running one cable to the controller.

On power-up, the Exit reader's LED will flash red, then green, then it will remain at amber.


icon will be displayed on the ribbon bar. Click this icon and you will see the following message.