NXT-MSC - Controller Internal Configuration
The following document explains how to access the
controller internal configuration and which configuration options can be
changed within Borealis.
1.0 Access Controller Internal Configuration Options
- From the Borealis main menu, click on Hardware >> Controllers.
- The controllers screen will appear.
- Use the Actions menu (located on the right) for the controller that you wish to edit.
- Select Configure.
- The controller's Internal Configuration form will appear.
- Use the drop-down menu to edit one of the following settings.
2.0 Controller Network Settings
These are the controller network settings that can be adjusted:
- Host Name - this is the host description for the controller. By default it displays the controller's MAC address.
- Network Method - The controller IP address can either be static or set to DHCP. By default, the controller will have a DHCP address but it should be set to a static IP address once the controller has been added.
- IP Address - This is the IP address that is assigned to the controller.
- Subnet Mask - The Subnet Mask for the controller.
- Default Gateway - The default Gateway IP address for the controller.
3.0 Session Settings
- Session Timeout - Configures the web session timeout value for this controller.
- Password Strength - Configures the minimum password strength for the controller.
4.0 Web Connection Settings
- Diagnostic Logging -
Select this option to create diagnostic information that will be
written to the debug file every 15 minutes (or when the MSC gateway
service is restarted.
- Disable Default User - Allows you to disable the default admin/password account.
- Door Forced Filter - Enable/disable filtering of door-forced events for this controller.
- SNMP - Enable/Disable the SNMP setting for this controller
- Web Server - Enables/Disables the Web Server for this controller
- Zeroconf Discover - Enables/Disables the Zeroconf discovery for this controller (used when scanning for NXT-MSC controllers.
5.0 Auto Save Settings
- Auto Save - Enable/disable the controller automatically saving settings when a configuration change is detected.
- Auto-Save Delay -
Specifies how much time to wait after host configuration change before
starting the save. The timer can be specified between 30 seconds and 30
minutes.
- Controller Start Up Routine Configuration
- Clear all Settings. Force a full download - The controller will clear its current configuration and will force a full download.
- Restore the controller from its last saved settings. This is the most secure option - For most systems the recommendation is for Restore to be enabled.
Related Articles
NXT-MSC Controller Setup
Add a New NXT-MSC Controller (2D or 4D) The following steps explain how to add an NXT-MSC controller to Borealis. It assumes that you have already followed the steps to add an NXT-MSC site to your system. During the steps to claim the hub you will ...
NXT-MSC Controller - Assign a Static IP Address
Configure the Controller With a Static IP Address Once the NXT-MSC controller has been added to Borealis you should configure the controller with a static IP address. This can be done via the controller's Internal Configuration menu. Important Note: ...
NXT-MSC Controller Firmware Upgrade
1.0 Introduction The following steps explain how to upgrade the firmware on an NXT-MSC or NXT-MSC controller via the Borealis user interface. 2.0 Check if the Controller Needs a Firmware Upgrade Once you have the controller(s) online, open live ...
Replace an NXT-MSC Controller
1.0 Introduction The following steps explains the correct method for replacing an NXT-MSC controller. Following these steps exactly ensures that the controllers, reader and access rights settings are retained and will not need to be reprogrammed. ...
NXT Controller Setup
1.0 Introduction The following document explains how to add a Standard NXT (2 or 4-door) controller to Borealis. It assumes you have already created a site (configured for Standard NXT) and have also added and claimed a hub to that site. Notes: ...