Specifications:
Unit Dimensions
• PXL-250/PXL-500/PXL-510 controller PCB with an SB-593 Satellite Board (with or without
an LCD-1 Alpha/
Numeric Display):
- 7.25 inches high by 6.00 inches wide by 1.75 inches deep, including wiring connectors
- (18.45 cm by 15.25 cm by 4.45 cm)
• Enclosure
- 9.70 inches high by 8.20 inches wide by 2.60 inches deep
- (24.65 cm by 20.85 cm by 6.60 cm)
Operating Temperature/Humidity Range
• 0°F to 140°F (-18°C to 60°C)
• 0% to 90% Relative Humidity, non-condensing
Controller with Satellite Board Power Requirements
• 12 VDC @ 1 Amp
Current Draw
• maximum current draw 270 mA for a controller plus reader current draw (refer to Table 1 for Reader current draw)
• 120 mA max for a PXL-250/PXL-500/PXL-510 Controller
• 150 mA max for an SB-593 Satellite Board
Table 1: Reader Current Draw
Reader Type
| MS-3000
| MS-4000 | MS-5000 | MS-7000 |
Current Draw
| 50 mA | 50 mA | 100 mA | 200 mA |
Output Relay Contact Rating
- 1 Amp @ 24 VDC
Input Device Configuration
• Door Sense normally closed
• Request to Exit normally open
• Global Unlock normally open, or
Auxiliary RTE A-Door normally open
Cable Requirements
• two conductor, AWG 22 or a larger gauge for all input connections
• two conductor, AWG 18 or a larger gauge for all output connections
Note: The Lock Output relay may require a heavier gauge of wire depending upon the
current demands of the lock and
the length of the lock wiring run.