Pop-up Alerts

Pop-up Alerts

Version 3.5.1.21 of Doors.NET supports what is known in the industry as Pop-Up Alerts.


When a hardware object (input, reader, controller, etc) is configured with this setting it will cause the Doors.NET user interface to become the 'Top-Most' application and the alerts grid will also come to the front (even if the Alerts grid has been closed).This feature works well with Sound Alerts for a greater level of event notification.


This article explains how to setup an input on a 4x4 as a Pop-Up Alert trigger when it is activated.

 

Setup Procedure

  • Got to Setup >> Hardware Setup >> All.
  • Add an NXT 4x4 module to one of the controller's buses.

 

Popup Alerts - Image 1

 

  • Expand the 4x4 inputs and rename that one that will be used as the pop-up event trigger (the alert will be generated when the input goes active).
  • Save.

 

Pop up Alerts - Image 2

 

  • Go to Setup >> Device Types.

 

 

  • Click the Add Device Type button and rename the new device type.
  • Select Make Active Window (Top Most) and Must Confirm.
  • Save.

 

Pop-Up Alerts - Image 4

 

  • Next, go to Setup >> Filters.

 

Pop Up Alerts - Image 5

 

  • Click the Add Filter button.
  • Rename and then save the new filter.
  • Click the Messages tab and select the specific Monitor Point - Alarm and Monitor Point - Secure message types.
  • Save.
  • Go to the Acknowledge tab and place a tick against Monitor Point - Alarm.

 

Pop Up Alerts - Image 6

 

  • Save the filter settings once more.
  • Now, you would need to go to the hardware tree again and select the input on the 4x4 which you have dedicated.
  • Ensure Advanced View is enabled so you can see all the hardware properties.

 

Pop Up Alerts - Image 7

 

  • Scroll down the input properties and locate Monitoring (near the bottom of the grid).
  • Apply the Filter and Device Type that you recently created.
  • Set Require Acknowledgment to Yes.

 

Pop Up Alerts - Image 8

 

  • Save the input settings.
  • Activate the input while Doors.NET is minimized and you will see the user interface become the top-most application.
  • Close down the alerts grid and just have the Hardware Setup page open, for example. The Alerts page will then automatically open when the alert is generated.

 

Pop Up Alerts - Image 9