LP4502 Controller Setup in Doors.NET
1.0 Introduction The setup for the LP4502 controller is very similar to the LP1502 and the LP2500. All LP controllers are pre-configured for use on a network, therefore additional TCP/IP configuration must take place in the field prior to placing ...
LP2500 Controller Setup in Doors.NET
1.0 Introduction The LP2500 provides a two-door interface with auxiliary I/O, including onboard I/O for 2 readers, 8 supervised inputs and 4 relay outputs. The controllers support a wide range of reader communication connections, including Wiegand, ...
LP1502 Controller Setup in Doors.NET
1.0 Introduction The LP1502 controller is an advanced access control platform by Mercury Security. They have direct hardware support for 2 openings and can scale to 64 access points. The LP1502 provide a two-door interface with auxiliary I/O, ...
LP1501 Controller Setup in Doors.NET
1.0 Introduction This section explains how to setup and configure an LP1501 controller with the Doors.NET software. All LP controllers are pre-configured for use on a network, therefore additional TCP/IP configuration must take place in the field ...
Mercury LP Series - Full Reference