True Mercury
Mercury EP Controllers - Assign a Static IP Address
Configure the Mercury EP Controller With a Static IP Address Once the controller has been added to Borealis you should configure it with a static IP address. This can be done via the controller's Internal Configuration menu. Important Note: Before ...
Add a True Mercury Site
1.0 Introduction The site determines which hardware type will be used. Once a site has been added you will then be able to add a hub (or multiple hubs) to the site. Each hub supports up to 32 doors. A site may represent a business location, a floor ...
Add a True Mercury Hub
1.0 Introduction A hub provides the communication link between the Borealis Cloud services and the field hardware (controller, readers and modules). Notes: - At least one hub is required per system. - Multiple hubs of the same controller type can be ...
MR62E Controller Setup
1.0 Introduction The following steps explain how to add an MR62E controller to Borealis. The most important thing to be aware of is the fact that you must first add an LP4502 controller to Borealis before you can add the MR62E. 2.0 Add an LP4502 and ...
MR51E Controller Setup
1.0 Introduction The following steps explain how to add an MR51E controller to Borealis. The most important thing to be aware of is the fact that you must first add an EP4502 controller to Borealis before you can add the MR51E. 2.0 Add an EP4502 and ...
MR16OUT Module Setup
1.0 Introduction The Authentic Mercury MR16OUT module enables expansion of Authentic Mercury intelligent controllers by offering 16-general purpose outputs as Form C relay contacts. The MR16OUT also provides individually configurable parameters that ...
MR16IN Module Setup
1.0 Introduction The Authentic Mercury MR16IN module enables expansion of Authentic Mercury intelligent controllers by offering 16-general purpose input circuits and two-programmable relay outputs. Borealis supports the use of Series 2 MR16IN modules ...
MR52 Dual Door Module Setup
1.0 Introduction The MR52 dual door interface panel with on-board flexibility to connect to a wide range of security devices. The MR52 is easy to install and provides the required I/O for interfacing two card readers, eight general-purpose input ...
MR50 Single Door Module Setup
1.0 Introduction The MR50 Series 3 is an enhanced SIO single card reader interface panel dedicated to individual door oversight and provides all the I/O needed for controlling a single door. Each MR50 connects one card reader, two general-purpose ...
LP4502 Controller Setup
1.0 Introduction The new Authentic Mercury LP Series Intelligent Controllers are Mercury Security’s next generation advanced access control platform that runs on embedded Linux. The enhanced platform offers an improved processor and increased memory, ...
LP1502 Controller Setup
1.0 Introduction The LP1502 is a powerful system processor module capable of managing two doors/readers “on board” and hundreds of I/O points via connection to additional door modules or MR16 I/O modules. Based on the intelligent, non-proprietary ...
EP4502 Controller Setup
1.0 Introduction The EP4502 is a powerful system processor module capable of managing two doors/readers “on board” and hundreds of I/O points via connection to additional door modules or MR16 I/O modules. Based on the intelligent, non-proprietary ...
EP1502 Controller Setup
1.0 Introduction The EP1502 is a powerful system processor module capable of managing two doors/readers “on board” and hundreds of I/O points via connection to additional door modules or MR16 I/O modules. Based on the intelligent, non-proprietary ...